This application is a calculation aid. Verify results against the applicable NEC edition, equipment instructions, local amendments, and the Authority Having Jurisdiction (AHJ).

Calculators

Every result shows its inputs, steps, NEC references, assumptions and warnings.

Colored tools below are ones you can open. Log in or sign up to unlock your trial tools.

Conductors & Raceways

Ampacity, derating, fill and box sizing

Voltage Drop

Voltage drop and percentage for a run, by NEC Chapter 9, Table 9 or the resistivity approximation.

NEC 2023Log in to unlock

Conductor Ampacity & Derating

Looks up base ampacity, then applies ambient temperature correction and adjustment for bundled conductors.

NEC 2023Log in to unlock

Medium Voltage Cable Ampacity

Looks up Type MV cable ampacity from NEC 315.60(C) by installation, then applies ambient correction.

NEC 2023Log in to unlock

Wire Ampacity Reference

Table 310.16/310.17 base ampacity by size, material and installation method.

NEC 2023Log in to unlock

Copper vs. Aluminum

Sizes a circuit in both materials (0–2000 V, Table 310.16/310.17/310.20) and compares the ampacity, size and rough cost delta. Supports parallel sets for loads above a single conductor's ampacity.

NEC 2023Log in to unlock

Conduit Fill

Checks conductors against the permitted fill for a chosen conduit type and trade size.

NEC 2023Log in to unlock

Raceway Sizing

Finds the smallest trade size of a conduit type that accepts a set of conductors.

NEC 2023Log in to unlock

Box Fill

Required box volume for the conductors, clamps, fittings, devices and grounds in an outlet or device box.

NEC 2023Log in to unlock

Pull & Junction Box Sizing

Minimum box dimension for a straight, angle or U pull, for conductors 4 AWG and larger.

NEC 2023Log in to unlock

Load Calculations

Service, feeder and branch-circuit loads

Continuous Load (125%)

Minimum conductor and overcurrent-device rating for a load with a continuous portion.

NEC 2023Log in to unlock

Dwelling Service Load

Standard-method service load for a dwelling, from floor area, appliances, range, dryer and space conditioning.

NEC 2023Log in to unlock

Optional Dwelling Load

Optional service load for a dwelling under 220.82, often smaller than the standard method.

NEC 2023Log in to unlock

Feeder & Branch-Circuit Load

Minimum conductor ampacity and device rating from continuous, non-continuous and motor loads.

NEC 2023Log in to unlock

Generator Sizing

Total connected load against a generator's rating, with a motor starting-surge check.

NEC 2023Log in to unlock

Panel Schedule Builder

Lays circuits into a panel and tallies spaces used, per-leg current and balance.

NEC 2023Log in to unlock

Energy Cost Estimator

Appliance wattage and daily runtime, priced at your electricity rate.

NEC 2023Log in to unlock

Load Current & Power

Convert between current, apparent power and real power for DC, single-phase and three-phase loads.

NEC 2023Log in to unlock

Protection & Grounding

Overcurrent devices and grounding conductors

Standard Overcurrent Device

Nearest standard fuse or breaker ratings above and below a required current, with the next-size-up conditions.

NEC 2023Log in to unlock

Equipment Grounding Conductor

Minimum equipment grounding conductor for an overcurrent device rating, including proportional upsizing.

NEC 2023Log in to unlock

Grounding Electrode Conductor

Grounding electrode conductor for a service, from the service-entrance conductor size.

NEC 2023Log in to unlock

Transformer Overcurrent Protection

Maximum primary and secondary protection for a transformer, by protection method — Table 450.3(B) at 1000 V and below, Table 450.3(A) above it.

NEC 2023Log in to unlock

Motors & Equipment

Motors, transformers, HVAC and EV supply

HVAC Circuit Ampacity & Protection

Minimum circuit ampacity and maximum overcurrent protection for air conditioning and refrigeration equipment.

NEC 2023Log in to unlock

EV Supply Equipment Circuit

Continuous-duty ampacity, breaker and conductor size for an EV charging circuit.

NEC 2023Log in to unlock

Motor Branch Circuit

Conductor ampacity, short-circuit protection and overload for a single motor, from the full-load current tables — including the DC rectifier, multispeed, wye-delta, part-winding and duty-cycle cases.

NEC 2023Log in to unlock

Multiple-Motor Feeder

Conductor ampacity for several motors plus other loads, at 125 percent of the largest motor and continuous load, plus the rest.

NEC 2023Log in to unlock

Group Motor Branch-Circuit Protection

Short-circuit and ground-fault protection for two or more motors, or motors and other loads, on one branch circuit — Cases A, B or C.

NEC 2023Log in to unlock

HP, Amps & Power Converter

Converts between horsepower, current, apparent power and real power.

NEC 2023Log in to unlock

Transformer Current

Full-load current on the primary and secondary windings from the kVA rating and winding voltages.

NEC 2023Log in to unlock

Solar PV

Array voltage, current and conductor sizing

PV Maximum System Voltage

Coldest-day array voltage from module open-circuit voltage, by temperature coefficient or Table 690.7(A).

NEC 2023Log in to unlock

PV Maximum Circuit Current

Maximum current for a PV source, dc-to-dc converter or inverter output circuit, before conductor sizing.

NEC 2023Log in to unlock

PV Conductor Sizing

Smallest PV circuit conductor satisfying both 690.8(B) tests, with the governing one named.

NEC 2023Log in to unlock

PV String Sizing

Permitted range of modules in series against an inverter's voltage window, at both temperature extremes.

NEC 2023Log in to unlock

PV Overcurrent Device

Overcurrent device rating for a PV circuit, checked against the module's maximum series fuse rating.

NEC 2023Log in to unlock

Inverter Output Circuit

Maximum current, required conductor ampacity and overcurrent device for an inverter output circuit.

NEC 2023Log in to unlock

Load-Side Interconnection

Checks a back-fed PV connection against the busbar under every arithmetic method in 705.12(B).

NEC 2023Log in to unlock

Feeder Tap Interconnection

Checks a power source connection to a feeder against every applicable test in 705.12(A).

NEC 2023Log in to unlock

Supply-Side Interconnection

Conductor size for a connection ahead of the service disconnect, against both the ampacity and the 705.11 floor.

NEC 2023Log in to unlock

PV Equipment Grounding Conductor

Grounding conductor for a PV circuit, including the assumed device where the circuit has no overcurrent protection.

NEC 2023Log in to unlock

Rapid Shutdown Checklist

Whether 690.12 applies, and the voltage and time limits the installation must meet if it does.

NEC 2023Log in to unlock

Required PV Labels

The marking a PV installation must carry, from how the system is built and interconnected.

NEC 2023Log in to unlock

Battery Backup Runtime

Estimated backup hours from a connected-load list and usable battery capacity.

NEC 2023Log in to unlock